Choose the lighting, the battery and the pole together
Sunlurio manufactures complete solar street light systems with poles. Start with your road width, a photo and the hours the lights need to run. We can help you choose the light output, battery capacity and pole arrangement together, and check whether the poles already on site can be used.
Lighting system
Lamp and optics, panel, battery, controller, and specified mounting and electrical parts
Pole package
Pole, arm, base plate and anchor hardware as listed in the offer
Road and operation
Road width, target light levels, mounting height, spacing, runtime, dimming and solar conditions
Site work
Assign civil design, foundation, installation and commissioning in the scope schedule
A new site with limited grid access is a good place to evaluate an off-grid solar package. Confirm there is a practical position for the panel with adequate exposure during the months that govern design. Check for future shading from trees, buildings and road furniture. Places with frequent fog, seasonal rain, high temperatures or heavy dust need those conditions stated in the sizing assumptions. If the owner needs a high output throughout the night, provide the target operating pattern early so the energy system can be considered together with the photometry.
An all-in-one unit groups components around the luminaire and can simplify some installation steps. Its panel position and lighting direction may have to work within the same mounting arrangement. An all-in-two design usually gives more freedom for panel orientation, with the exact battery placement verified by model. A split design separates major components and can give the project more choices for mounting and access, while adding interfaces the installer must manage. Compare maintenance access, cable protection, panel brackets and pole loading in the context of the site. The choice affects more than the number of boxes shipped.
Start with an integrated unit where the road is open, the panel has good sun and the pole position suits both the light and the panel. Where the light must face the road but the panel needs another angle, look at an all-in-two system. If trees or buildings shade the pole itself, check whether a split system can put the panel in a reliably sunny position and whether the cable route and supports are practical. If there is no workable panel position, review another pole location or a mains-powered option before committing to solar.
Start with a road photo and whichever dimensions you already have. Mark the part you need to light, such as both lanes or the lanes and a footpath. Tell us about dark spots that matter to the owner, like a crossing or a bend. With the road width, pole spacing and mounting height, we can identify what the lighting calculation needs. Use the proposed optic, arm and tilt in that calculation. If the pole positions are fixed, share them before asking for a lighting layout. See the DIALux report and illuminance maps you can request for project review.
Tell us when people use the road and when the light can dim. Example 1. Energy used at the light. Four hours at 40 W and eight hours at 20 W add up to 320 Wh over one night. To size the system, we still need the battery-side draw, usable battery energy and the expected charging in the lowest-sun month. If the owner needs extra nights of reserve, tell us how many and at which brightness. We can then check the proposed schedule and recovery time against the project conditions.
Start from the energy the battery actually has to supply. Example 2. A separate battery and panel sizing scenario. If the system draws 360 Wh per night and the site receives three peak-sun hours per day in its lowest-sun month, the theoretical panel size is 120 Wp before charging and site losses. The final panel must allow for those losses and the time needed to recharge after low-sun days. For two nights of reserve at the same draw, plan for 720 Wh of usable energy. Convert that to rated battery capacity using the usable fraction allowed for the selected battery and temperature. Power in W sets the load at any moment, Wh tracks energy over time, and Wp is the panel rating under standard test conditions.
One enquiry listed 23 sets, with two lights on each of 23 poles. That meant 46 luminaires and 23 poles. The panel, battery and controller counts depended on how the lights would be powered and controlled. Counting those items from the number of sets alone could leave the installer short of equipment.
When you send a pole count, tell us how many lights each pole carries and whether they need to run on the same schedule. We can work through whether to share the panel, battery and controller, which arms and anchors the system needs, and which items the civil team will provide. Start with a road photo and expected lighting hours if the layout is still open.
For the light head, identify the exact model and optics. For the solar and battery equipment, ask for the configuration and wiring documentation that matches that model and its operating schedule. Confirm where the panel and battery sit, how their mounting parts are supplied and what lengths or connectors are included if the components are separate. Ask for the path of exposed cables and whether the project specifies safeguards for publicly accessible equipment.
For the pole, name the height, arm arrangement, finish and equipment loads. Confirm whether the order includes the flange, anchor bolts, nuts, washers and setting template, and identify the drawing that coordinates them. Civil design, excavation, concrete, installation labour and commissioning should each have a named owner in the scope schedule. Share the equipment and civil-work lists with the local contractor before confirming the layout. The site team can then check which drawings, anchors and finished foundation levels they need before the equipment arrives.
Ask for one sample or agreed reference configuration before ordering a full batch. Give it a reference that appears on the parts list and the documents. The electrician can use that reference to check the settings, and the installation crew can use it to find the correct bracket, arm and mounting hardware.
Match the luminaire and optics to the road layout and the panel and brackets to the agreed pole position. For a pole that is already installed, share a photo and the measured spigot. The proposed mounting hardware, equipment weight and exposed area give the project’s structural reviewer a starting point.
Ask for the pack voltage and capacity, controller settings and the planned full-output and dimmed periods together. The same amp-hour figure can mean different stored energy at different voltages. Confirm which settings apply to the supplied controller so the installer knows what to expect on the first night.
Before approving the sample, agree which physical checks and operating checks the team will repeat. Confirm the connectors mate, the mounting points are accessible and the controller displays the expected status. On site, check panel orientation and shading in daylight, then review the lighting and dimming schedule at night against the agreed plan.
Ask for carton marks and a packing list that identify the kit, brackets, cables and any spare components. If a part needs to change, agree the replacement and any drawing or lighting-file revision before release. That gives the maintenance team a traceable list to use when they need a replacement.
If you are preparing a tender, send the owner’s schedule or a list of the documents they request. We can help match the available drawings, lighting information and component details to the proposed configuration.
Provide the existing mounting height, arm dimensions and spigot details. Include photos of the mounting point and base, and any drawings or records for the pole and foundation. A separate panel can change the loads on equipment that was originally selected for an ordinary grid-powered light. The team should review the condition and structural suitability of the pole and foundation, including any parts that will be left in service. For groups of poles installed at different times, check that measured dimensions represent each type in the field.
For a main road in Burkina Faso, the tender reference listed 80 W rated luminaires and 3.2 V, 150 Ah batteries, equal to 480 Wh nominal per battery. The project listed a 12-hour night. Running at 80 W for all 12 hours would require 960 Wh at the lamp alone. Use the actual running power and dimming schedule when estimating energy for a similar road.
In Saudi Arabia, 450 sets for urban roads used a 60 W SL-PRO-JD lighting unit, a 45 Wp solar panel, a 12 V, 50 Ah battery (600 Wh nominal) and a 6 m pole. The system used programmable time-based dimming. The local lighting hours, solar conditions and owner’s brightness requirements determine whether either setup fits your project.
In Abuja, Nigeria, Sunlurio supplied the luminaires, solar panels, batteries, controllers, poles and anchor bolts as a complete package. The photos show field assembly and the lights in use. If a similar project uses existing poles, start by checking the panel brackets, arm connection and base so the lighting package fits what is already there.
The Saudi urban-road reference above links a 60 W SL-PRO-JD light, 45 Wp solar panel, 600 Wh nominal battery and 6 m pole. Use the same format to review a package for your site.
Start with the road layout. Mark each pole, the number of heads, arm reach and mounting height. Then record the agreed lighting schedule and the proposed optic for each group of poles, including any different requirements at junctions.
Write light input in watts, usable battery reserve in watt-hours and panel rating in Wp. Attach the night schedule and the seasonal charging assumptions behind the selection. Use the lighting calculation to review coverage and the energy review to check the schedule can be sustained.
List heads, poles, arms and anchor sets separately and attach the current pole and base drawing. During receiving, take one pole mark from the layout and trace it to its head, battery and panel records and the matching crate labels.
Before delivery, agree the drawing package and packing identification. A shipment that groups mechanical parts by pole type and electrical parts by luminaire configuration is easier to check on arrival. For commissioning, use the approved site procedure to verify orientation, connection, controller settings and operation after dark. Ask who records the initial settings and maintains the equipment list. For future changes, maintenance teams benefit from access to the battery, optical file, wiring diagram and agreed replacement references. Confirm the warranty terms for the individual components and how the buyer should identify equipment when requesting support.
If the site already has poles, start with a lighting-only plan. Send the arm diameter, insertion depth, mounting height and a picture of the pole base. If the new light needs a separate panel or battery box, include the mounting position and equipment details for the structural review. A usable lamp connection is one part of the decision. The pole and foundation also need to carry the new equipment.
Choose a complete package if the new pole, arms, supports and anchors need to be coordinated from the start. Where a road uses different optics, panel positions or pole types, give each variant a mark on the layout and equipment schedule. Use those marks on the packing list so each crew receives the right parts for its road section.
In one tender, project documents listed two battery capacities, 384 Wh and 538 Wh, and two panel sizes, 80 W and 100 W. The buyer needed to know which pair went with the proposed lighting schedule. Use one equipment revision for the energy calculation, datasheet and installation details before you approve the configuration.
For your submittal, tell us which option you plan to submit. We can help check the equipment schedule, datasheet and lighting calculation against that option, including the luminaire and optic, battery and panel, and the pole and arm shown on the drawing. If the authority needs an IES file, a particular report or a written warranty, name the requirement before you place the order. That gives us a chance to identify the matching document or flag anything still pending.
When you have two options, compare what the road will receive. Keep the same lighting target, hours of use and low-sun conditions. Then check the night-time brightness schedule, battery capacity in usable Wh, solar panel in Wp and recovery time after a run of cloudy days. If a second option changes the pole height or spacing, run the lighting calculation for that layout and check the dark spots as well as average illuminance.
Keep the layout that meets the lighting target with a practical panel position and enough energy for the required schedule. If two layouts meet the target, consider which one makes it easier for your team to clean the panel, reach the battery and replace a controller. We can help you compare those choices when you share the road layout and site conditions.
Check the component schedule and the civil scope together. The equipment list can include anchors and a template if agreed. The drawings and contract should establish the responsibility for civil design, concrete and on-site operations. Ask for separate lines where a cost or responsibility differs between bidders.
Yes. Add the site location, a photo and the hours you need light. That is enough to start discussing the layout. To choose the final system, add the lighting target, pole spacing and any reserve requirement for low-sun days.
Compare the optical distribution, actual output and the result on the road as well as input power. Light directed outside the target area may add little useful illumination. A higher actual load also changes battery and solar sizing. Compare proposals using the same site geometry and operating schedule.
Count both luminaires and their actual simultaneous load. Review the arm arrangement, optics for each direction and the loading that reaches the pole and foundation. Confirm the battery architecture, controller capacity and wiring path with the exact layout before using a single-head proposal as a reference.
Consider stand-alone solar first where bringing in a power cable would mean long trenching and the panels have a reliable sunny position. Where mains power is dependable and the road needs sustained high output, compare a mains-powered design as well. Share the distance to the power connection, panel shading and the required night-time output. Those three inputs usually narrow the choice.
Multiply the nominal voltage by Ah to compare stored energy. At 3.2 V, 50 Ah is 160 Wh. At 12 V, 50 Ah is 600 Wh. Then check how much of that rated energy the battery can deliver within its allowed discharge range and temperature. Use the usable Wh with the actual nightly draw to size the reserve.
Write the lighting hours and brightness for each night in the requirement. Three 12-hour nights add up to 36 lighting hours under that schedule. State whether to assume no charging during the reserve period or some solar recharge. Use the actual watts at each brightness step and agree how soon the battery needs to recover afterwards.
Mark where the road is dark, such as between poles or at a crossing. Send the pole layout, mounting height, arm outreach and the road width. Start by testing the proposed optic and mounting angle in the lighting calculation, then compare the darkest areas and uniformity with the owner’s target. If the result is still short, review the spacing or add a lighting point before changing the power setting.
Agree which sample and controller setting the site team will use. During the day, check panel position, charging status and the fit of the arm and brackets. At night, check when the light starts, when it dims and what the road looks like at each required stage. Record the agreed setting and sample ID so the rest of the installation uses the same reference.
Send a road photo or layout, your pole count, lights per pole and expected lighting hours. If the site already has poles, include a photo or the arm dimensions. Add any drawings in the email.
WhatsApp us