Products / LED Modules
SUNLURIO / LED MODULES & COMPONENTS
Select LED modules and components for new mains-powered luminaires, existing installations and spare parts programmes.
Have an old module or a driver label? Start with photos, dimensions and quantity. We check physical fit, driver compatibility and where the light needs to fall.
AC
For new luminaires, municipal maintenance and spare parts programmes.
Confirm local AC supply and driver input. At the module, match constant current, output voltage window and series or parallel wiring. A mains input rating does not permit connecting a DC module directly to AC.
Provide road width, pole height, spacing and lighting targets. Check illuminance or luminance, uniformity and glare with the IES or LDT file for the proposed luminaire.
Check supply range, transient surge and sustained overvoltage separately. For retrofits, also verify earthing, sealing, operating temperature and tender requirements.
MODELS
Mains street lighting comes first. Use the figures to shortlist a configuration, then confirm the order specification against the approved drawing and test report.
Compact square or rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 30 / 40 W · 150–160 lm/W |
Check outline, hole spacing and cable exit for each model.
Compact square or rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 60 W · 155–173 lm/W |
Check outline, hole spacing and cable exit for each model.
Compact square or rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 60 W · 155–173 lm/W |
Check outline, hole spacing and cable exit for each model.
Compact square or rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 60 W · 155 / 180 lm/W |
Check outline, hole spacing and cable exit for each model.
Compact square or rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 60 W · 155 / 180 lm/W |
Check outline, hole spacing and cable exit for each model.
Rectangular
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | 3000 / 4000 / 5000 / 5700 K |
| Power and efficacy | 50 / 60 W |
Check optic orientation and mounting shoulder.
Glass-front rectangular
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | To be confirmed |
Confirm glass, gasket and spare parts scope.
Long rectangular
Product photograph pending. Ask for the confirmed photograph and mounting drawing for SL-LM008.
| Parameter | Specification |
|---|---|
| LED packages | 2835 / 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | 300 × 70 × 35.1 mm / 480 g |
| CCT | To be confirmed |
| Power and efficacy | 50 / 60 W · 140–175 lm/W |
Reference envelope: 300 × 70 × 35.1 mm; confirm against drawing.
High-output rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 50–80 W · 173–185 lm/W |
Check driver, current and thermal clearance first.
High-output rectangular families
| Parameter | Specification |
|---|---|
| LED packages | 5050 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 50–80 W · 173–185 lm/W |
Check driver, current and thermal clearance first.
Glass-front, near square
| Parameter | Specification |
|---|---|
| LED packages | 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | 201 × 180 × 48 mm / 580 g |
| CCT | 3000 / 4000 / 5000 / 5700 K |
| Power and efficacy | 50–80 W · 150–180 lm/W |
Reference footprint: 201 × 180 mm; verify mounting holes.
Round white-light module
| Parameter | Specification |
|---|---|
| LED packages | 3030 |
| Base material | ADC12 |
| Ingress protection | IP65 |
| Dimensions / weight | Ø75–120 mm |
| CCT | 2700 K |
| Power and efficacy | To be confirmed |
Reference diameter range: 75–120 mm; confirm variant and optics.
Round RGBW landscape module
| Parameter | Specification |
|---|---|
| LED packages | 3030 / RGBW |
| Base material | ADC12 |
| Ingress protection | IP65 |
| Dimensions / weight | To be confirmed |
| CCT | 2700–5700 K + RGB |
| Power and efficacy | To be confirmed |
Confirm channels, controls and optics separately for landscape projects.
Tunable white
| Parameter | Specification |
|---|---|
| LED packages | 3030 |
| Base material | 6063-T5 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | 3000–5700 K |
| Power and efficacy | 60 W |
Confirm channels, CCT range and mechanical drawing.
Die-cast family
| Parameter | Specification |
|---|---|
| LED packages | 2835 / 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 40–60 W · 140–182 lm/W |
Confirm outline, thermal interface and fasteners.
Die-cast family
| Parameter | Specification |
|---|---|
| LED packages | 2835 / 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | To be confirmed |
| Power and efficacy | 40–60 W · 140–182 lm/W |
Confirm outline, thermal interface and fasteners.
Die-cast family
Product photograph pending. Ask for the confirmed photograph and mounting drawing for SL-LM017.
| Parameter | Specification |
|---|---|
| LED packages | 2835 / 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | 3000 / 4000 / 5000 / 5700 K |
| Power and efficacy | 40–60 W · 140–175 lm/W |
Confirm outline, optical variant and sealing design.
Die-cast family
Product photograph pending. Ask for the confirmed photograph and mounting drawing for SL-LM018.
| Parameter | Specification |
|---|---|
| LED packages | 2835 / 3030 / 5050 |
| Base material | ADC12 |
| Ingress protection | IP66 |
| Dimensions / weight | To be confirmed |
| CCT | 3000 / 4000 / 5000 / 5700 K |
| Power and efficacy | 40–60 W · 140–175 lm/W |
Confirm outline, optical variant and sealing design.
White LED board
4000 K · CRI 70 · 1015 lm · 203 lm/W · IP20 · 70.6 × 49.5 × 1.6 mm · 16 g
Short dual-channel board
2200 / 4000 K · 49.5 × 121.4 mm · 120° · IP00 · 350 mA rated / 900 mA max · Ta −40…80 °C · Tc ≤95 °C · 3 SDCM
Long dual-channel board
2200 / 4000 K · 49.5 × 223 mm · 120° · IP00 · 350 mA rated / 900 mA max · Ta −40…80 °C · Tc ≤95 °C · 3 SDCM
LED board with NTC
2200 / 2700 / 3000 / 4000 / 5700 / 6500 K · IP20 · ≤5 SDCM
2×2 / 2×4 / 2×6 / 2×8 · 530 mA · 12 / 23 / 34 / 45 V · 6 / 12 / 18 / 24 W · 1110 / 2220 / 3330 / 4450 lm
5050 LED board family
8 / 12 / 16 / 24 LEDs · ≤3 SDCM · MCPCB
Sealed rectangular module
40 / 50 / 60 W · 7600 / 9250 / 10800 lm · 50–64 VDC · 700 / 850 / 1000 mA · IP68 · 275 × 75 × 48 mm · 520 g
30 W narrow rectangular module
30 W · 110–160 lm/W · 42–52 V · CRI 70 · 55 × 150° / 80 × 150° · 300 × 70 × 40 mm
01 / YOUR TASK
Buying an LED board, replacing a complete light engine and developing a new street light are different tasks. Choose the situation closest to yours. This makes the next technical conversation more useful and avoids asking you for information that does not affect your decision.
Prepare the original luminaire and component labels, front and rear photographs, overall dimensions and mounting hole positions. A light that does not work may have a driver, connector or control problem. Diagnose the fault before ordering a replacement LED board.
Start with the lighting task, available housing space and cooling arrangement. Define a combination of LED board, optics, driver and mounting parts. Verify the proposed assembly with a sample before fixing the production configuration. This is especially important when changing more than one component.
Connect each spare part to a luminaire model, revision and installed quantity. List modules, drivers, surge protectors and seals separately. A box labelled accessories is not useful if the maintenance team cannot identify which light each item belongs to.
02 / MODULE STRUCTURES
Start with the structure, then confirm the available model and configuration. These categories involve different cooling, protection and installation responsibilities. Use the distinctions below to describe what you need rather than guessing a model number. The actual component combination and supply conditions are established for the selected product.
A starting point for luminaires with a defined housing and cooling structure. The board carries the LEDs and connections; it is not a finished weatherproof light engine on its own.
Check current and voltage, board dimensions, LED spacing, compatible optics and the thermal contact surface.
A possible route for modular luminaires or verified complete-unit replacement. Consider the light source, optics, cooling and sealing as one assembly, while still checking how it fits the host luminaire.
Check overall dimensions, fixing points, connectors, sealing details, protection evidence and access for maintenance.
For projects with a defined light colour or distribution requirement. A dual-channel board or a pedestrian-crossing optic should not be treated as a direct substitute for a standard white road-lighting module.
Check channel limits, control method, mixed output, photometric data and the installation orientation.
03 / COMPONENTS MATTER
You can describe a requirement for an individual component, a matched combination or a project spare-parts package. Separate supply, minimum order quantities, availability and lead times must be confirmed. The quotation should make clear which parts are already included in the module assembly.
OPTIONS
Specify a preferred brand or ask us to match components to the operating conditions.
In purchasing, “LED chip” often means the packaged LED. The die is the light-emitting semiconductor inside the package. You can specify either or both; a brand or a package size alone does not identify a part.
| Options | What to confirm |
|---|---|
| LED die brands: Sanan Optoelectronics, HC SemiTek, Zhaochi Semiconductor, Changelight | For die-origin requirements, confirm the die part number, packaging supplier and lot traceability. Accept the configuration against the packaged LED specification and module test data. |
| Packaged LED brands: Hongli Zhihui, Refond, NationStar, APT Electronics, Tiandian Optoelectronics | Common package sizes: 2835, 3030 and 5050. Confirm the full part number, operating current, forward voltage, CCT, CRI, colour tolerance, optic alignment and thermal conditions. |
Match the driver to the module first, then select dimming and control features. Drivers with the same wattage can have different output currents and voltage windows.
| Options | What to confirm |
|---|---|
| Mainland Chinese options seen in projects: Inventronics, MOSO, Lifud, SOSEN and Eaglerise | Confirm the outdoor series, local AC input range, constant-current output and voltage window, dimming protocol, ingress protection, surge test conditions and required approvals. |
| Another option commonly sourced in China: MEAN WELL (Taiwan brand) | Compare at the same operating point. For 0–10 V, DALI or programmable dimming, verify the exact series and suffix. |
Use a solar controller with constant-current LED output, or pair a charge controller with a separate DC constant-current driver.
| Options | What to confirm |
|---|---|
| Solar control options: SRNE and EPEVER | Verify whether the exact series provides constant-current output. Match battery chemistry and voltage, PV input, night dimming and low-voltage protection. A standard charge controller load output should not be assumed suitable for a bare LED module. |
Brands are available for quotation review. Confirm compatible parts, lead times and approvals in the written quotation for the selected SL configuration.
04 / COMPARABLE SPECIFICATIONS
The same number can mean different things under different test conditions. Use the fields below to request a model-specific specification at your intended colour temperature, current and assembly. Agree which values are nominal, which are minimum guarantees, and which conditions apply before comparing alternative products.
| Parameter | The practical question | What to agree |
|---|---|---|
| Actual power, W | Is this LED power, module-terminal power or complete-luminaire input? | State each relevant boundary at the intended current, temperature and driver configuration. |
| Flux, lm, and efficacy, lm/W | How much light is produced, and for how much electrical input? | Identify lenses, glass and driver losses included in the measurement; state thermal stabilisation conditions. |
| Current, mA, and forward voltage, V | Can the driver operate the assembly correctly when cold and hot? | Provide rated and maximum current, together with the operating voltage limits. A nominal voltage alone is insufficient. |
| CCT, CRI and SDCM | What colour is the light, and how consistent will batches appear? | Confirm the selected colour temperature, colour rendering and colour tolerance, rather than using another variant’s peak efficacy. |
| Distribution and IES/LDT | Will the light reach the intended surface? | Match the file to the LED, optic, power and orientation used in the proposed assembly. |
| Ambient and case temperature | How hot is the environment and the defined measurement point? | Distinguish ambient temperature from component temperatures and state mounting and derating conditions. |
| IP, IK and corrosion protection | What environmental and mechanical conditions are covered? | Identify the tested object and assembly. An ingress rating does not replace corrosion evidence. |
| Lifetime and warranty | How is output maintained, and who covers a failure? | State lifetime conditions and failure definitions; list warranty duration, start date and responsibilities separately. |
OPTICS
The same LED assembly can behave very differently with another lens. Roads, parking areas, pedestrian crossings and gardens need different distributions. Share road width, mounting height, pole spacing, arrangement and the required lighting criteria before choosing an optical combination.
An IES or LDT file describes how light is distributed. A DIALux calculation places that distribution into a road or site model to assess the required average level, uniformity, glare and spill light. A curve image or a lumen figure alone does not show that the installation will comply. Photometric data must remain traceable to its tested configuration; it should not be edited simply to produce a more favourable calculation. If the source output or optics change, check whether the file still represents the proposed product.
THERMAL DESIGN
LED packages, board construction, interface material, fixing pressure and the heat sink work together. Aluminium grade or heat-sink weight alone cannot establish operating temperature or life. Replacing a thermal pad with a different thickness can change contact and performance.
For hot, humid or coastal locations, describe the actual environment and the required protection. A higher ingress rating does not automatically solve condensation, corrosion or overheating. Validate the proposed module in its intended housing. A board measurement under laboratory conditions is not a promise of complete-luminaire performance at a high outdoor ambient temperature. Ask for measurement-point definitions, mounting conditions and applicable derating information before relying on a lifetime claim.
05 / REPLACEMENT & SERVICE
Similar appearance, fixing holes and rated watts do not establish electrical, thermal or optical compatibility. Identify the original configuration and fault first. The right action may be replacing a board, a complete module, a driver or the luminaire rather than changing every component.
06 / SOLAR SYSTEM MATCHING
A more efficient light source may improve energy use, but changing the module does not by itself guarantee all-night operation. Actual LED load, driver and control consumption, hourly dimming, usable battery energy and charging in the least favourable month need to be considered together.
Battery voltage is not necessarily the LED operating voltage. After a module change, check controller output limits, maximum current, low-battery operation and temperature protection. Road spacing, mounting height and optics still determine whether the light is useful on the surface. An energy-saving percentage is not a substitute for a lighting calculation. Where the existing system cannot be identified, collect the controller, battery and module information before proposing a replacement that could change its operating behaviour.
07 / CONFIGURATION-SPECIFIC DOCUMENTS
Tell us whether the documents are for initial selection, sample evaluation, consultant review or a tender. Agree which files can be supplied, their revision, responsible party and delivery date. We help you match the available documents to your selected components and identify any additional testing needed for your project.
| Stage | Documents to agree | Purpose |
|---|---|---|
| Selection and quotation | Configuration sheet, itemised bill of materials, inclusions, exclusions, interface dimensions, quantity and trade terms. | Make competing proposals comparable within the same supply boundary. |
| Lighting design | Configuration-specific IES/LDT, site inputs and calculation assumptions; DIALux assessment where required and agreed. | Show which optics and site were assessed; a simulation is not site acceptance. |
| Sample and technical review | Drawings, datasheets, applicable report and certificate register, revisions and deviations. | Check that evidence covers the proposed LEDs, driver, construction and power. |
| Installation and service | Exploded drawing, part references, instructions, permitted replacement personnel and sealing-restoration requirements. | Help the maintenance team identify, replace and verify the correct component. |
08 / SUPPLY & SPARES
One quotation for an LED module may include only a populated board. Another may include optics, a heat sink, leads or a driver. Confirm the bill of materials before comparing totals. Samples, minimum quantities, production timing, packaging and warranty depend on the selected configuration and order; they should not be assumed to apply across every product.
Set spare quantities using the installed model mix, critical parts, maintenance capability and contract requirements. A percentage used on a previous project is not a universal rule. Discuss substitutes, discontinuation notices, free-of-charge coverage, freight and site labour separately. Give each spare a useful label so that a local technician can trace it to the correct luminaire revision. For a tender, distinguish mandatory requirements, proposed alternatives and unresolved points instead of describing an unverified offer as fully compliant.
09 / FAQ
Yes, you can start with an individual-component request. The exact part reference, original revision, dimensions, electrical interface and material need to be checked before separate supply conditions are confirmed. Send a photo or part number and your required quantity. We will check the matching component and confirm availability for your order.
Power alone is not a replacement specification. Two assemblies can use different currents, voltage ranges, circuits and cooling conditions at the same wattage. Even if the replacement lights up, temperature, distribution and driver operating limits still need to be checked. Operation is not the same as verified compatibility.
These names mainly describe package size, not a quality grade. Compare the exact LED part number, operating current, output, optics, thermal path and cost. Keep colour temperature, colour rendering and thermal conditions consistent when evaluating alternatives. A package label by itself cannot identify the most suitable design.
First establish whether the figure refers to the LED package, module or complete luminaire. Then define colour temperature, colour rendering, current, optics and temperature. Any guarantee needs to be tied to the selected configuration and applicable evidence. We help you compare options at the same current, colour temperature and thermal conditions, so the efficiency figure is useful for your design.
It can be an internal component of an appropriately designed luminaire, provided the housing supplies suitable protection and the electrical and thermal design is correct. The board itself should not be exposed to rain. Verify protection on the finished assembly, including its joints, wiring and installation conditions.
Check ageing, dirt, the driver and optics first. Increasing power may raise temperature and glare or exceed the driver capability without improving useful road coverage. Assess the complete combination against the lighting task before changing the load. This avoids creating a second problem during a repair.
A receptacle is one part of a system. Confirm the specific connector, pins, power supply, driver dimming interface, control node, network and platform. List receptacles, shorting caps and controllers separately. A mechanical interface does not establish communications compatibility or include a software service.
Provide the required standards, document format, proposed model and deadline. The next step is to establish which existing documents apply, what must be added and whether there are deviations. A certificate, a full test report and a manufacturer declaration serve different purposes and should not be substituted without agreement.
No. Lifetime describes output maintenance or failures under defined operating conditions. Warranty defines a period, start date, covered parts and remedies. Check the LEDs, driver and sealing conditions separately, and use the terms agreed for the order. A lifetime figure is not a promise of free replacement for that number of years.
No. Start with whether you are developing a new light or replacing an existing part, what you need, quantity and destination. Photographs or existing files can follow. The useful next step is identifying the missing information that affects selection, rather than asking you to fill in every possible technical field.
English selection edition · 18 November 2026. Includes the 27 SL module references and accessory groups. Use these files to shortlist components, then send us your SL reference and project requirements for a matched configuration and quotation.
For a new mains-powered luminaire, see LED Street Lights. For optical calculations, see IES / LDT support. For production verification, see manufacturing and quality.
Send the SL model, quantity, destination and any available photos or driver labels. We will identify the missing details for selection.
WhatsApp us