LED Street Lights for Municipal Road & Retrofit Projects
- Type II / III Road Optics
- AC 100–277V
- 10kV / 20kV SPD Options
- IES / LDT Files
- Municipal Retrofit Support
AC LED Street Light Project Inputs for EPC Review
Model Recommendation
Share road width, pole height, spacing, mounting arm, voltage, and lighting target so we can recommend a suitable AC LED street light model.
IES / DIALux Review
For consultant or EPC review, we can support IES/LDT files and DIALux / Relux lighting simulation after project inputs are confirmed.
Tender Document Pack
For BOQ or tender-stage projects, we can help prepare datasheet, model mapping notes, drawings, IES/LDT, and technical clarification support where applicable.
What Buyers Should Confirm Before Quotation
Road Width / Area Size
Confirm carriageway width, lanes, sidewalk, parking area, or yard size.
Pole Height
Confirm existing or planned pole height and whether the project is new-build or retrofit.
Pole Spacing
Confirm distance between poles and whether poles are single-side, double-side, or staggered.
Mounting Arm
Confirm arm length, arm angle, top diameter, side-entry or post-top mounting.
Voltage & Grid Condition
Confirm AC voltage, grid stability, surge risk, and cabinet or wiring condition.
Optics & Lighting Target
Confirm target lux, uniformity, lighting class, beam distribution, and road application.
Driver, SPD & Protection
Confirm driver requirement, SPD level, IP/IK requirement, temperature, humidity, and coastal conditions.
Required Documents
Confirm whether datasheet, IES/LDT, DIALux, drawings, BOQ notes, or tender support are required.
Engineering Note: Do Not Select LED Street Lights by Wattage Only
The same wattage can produce different lighting results depending on optical lens, LED efficiency, pole height, spacing, road width, mounting angle, driver, SPD, and project requirements. For EPC, municipal, and retrofit projects, model selection should be checked with project inputs and document requirements before quotation.
Quick Selection Guide for AC LED Street Light Models
SL-AC-JG
Best for:Municipal road lighting and standard AC street light replacement projects.
Confirm:Road width, pole height, spacing, arm size, voltage, and target lighting level.
Documents:Datasheet, IES/LDT, DIALux support, and BOQ matching notes where required.
SL-AC-JG01
Best for:Public road programs that need consistent appearance, repeat ordering, and stable model selection.
Confirm:Project quantity, pole layout, voltage, SPD level, optics, and required tender documents.
Documents:Datasheet, IES/LDT, model mapping, and project document pack.
SL-AC-ABS
Best for:High-lumen public roads, wide roads, and area lighting applications requiring stronger output.
Confirm:Mounting height, road width, target lux, uniformity, heat dissipation, and SPD level.
Documents:IES/LDT, DIALux / Relux support, datasheet, and technical review notes.
SL-AC-JG02
Best for:General AC road lighting and project-based replacement programs.
Confirm:Existing pole height, arm type, input voltage, road width, and installation environment.
Documents:Datasheet, IES/LDT, drawings where applicable, and BOQ matching notes.
SL-AC-DR03
Best for:Modern road retrofit projects and street lighting replacement applications.
Confirm:Existing luminaire type, mounting arm, pole spacing, voltage, and lighting target.
Documents:Datasheet, IES/LDT, retrofit comparison notes, and DIALux support where required.
SL-AC-WM
Best for:Compact roadway, parking area, campus road, and public-area replacement projects.
Confirm:Mounting height, installation method, voltage, area size, and target illumination.
Documents:Datasheet, IES/LDT, basic layout support, and model recommendation notes.
SL-AC-RD02
Best for:Road, municipal, commercial, and parking lighting projects requiring flexible model selection.
Confirm:Pole spacing, mounting height, beam distribution, SPD requirement, and ambient condition.
Documents:Datasheet, IES/LDT, DIALux support, and tender document pack where applicable.
SL-AC-YSM
Best for:Export-specific road lighting projects requiring appearance review and configuration matching.
Confirm:Country, voltage, project standard, road type, pole height, and required document list.
Documents:Datasheet, IES/LDT, model confirmation, and BOQ / tender support where required.
AC LED Street Light Series Overview
EPLUS SA — Single-Arm Road Lighting
Best for:Urban roads, municipal streets, industrial access roads, and standard single-arm pole layouts.
Key review points:Pole height, road width, pole spacing, arm length, voltage, optics, SPD, and required IES / DIALux files.
EPLUS DA — Double-Arm Road Lighting
Best for:Boulevards, dual carriageways, highways, campus roads, and center-pole double-arm installations.
Key review points:Road arrangement, two-side distribution, mounting height, arm configuration, optical layout, and lighting uniformity.
EPLUS-JG — Retrofit Street Light Head
Best for:Existing pole retrofit, luminaire replacement, municipal upgrade programs, and BOQ-based replacement projects.
Key review points:Existing pole arm, mounting interface, voltage, target lighting level, old fixture replacement, and tender document mapping.
Series Selection Matrix
EPLUS SA
Typical Application: Single-arm municipal road lighting, urban street, industrial access road
Main Project Inputs: Road width, pole height, spacing, arm length, voltage, optics, SPD
Document Support: Datasheet, IES/LDT, DIALux support, BOQ notes where required
Recommended Start Point: Use for standard single-arm road lighting and new-build municipal projects
EPLUS DA
Typical Application: Double-arm road lighting, boulevard, highway, dual carriageway, campus road
Main Project Inputs: Pole arrangement, two-side distribution, mounting height, uniformity target, arm configuration
Document Support: IES/LDT, DIALux / Relux support, datasheet, technical review notes
Recommended Start Point: Use for center-pole or double-arm lighting layouts
EPLUS-JG
Typical Application: Street light head replacement, existing pole retrofit, municipal upgrade program
Main Project Inputs: Existing arm, top diameter, mounting method, voltage, old fixture type, target lighting level
Document Support: Datasheet, retrofit notes, IES/LDT, BOQ model mapping
Recommended Start Point: Use when poles remain but luminaires need replacement
EPLUS SA — Single-Arm LED Street Light
EPLUS SA is used when the project requires a practical AC LED street light for single-arm road lighting. Model selection should be checked against pole height, road width, pole spacing, mounting arm, voltage, optical distribution, SPD requirement, and required engineering documents.
- For single-arm road and street lighting layouts
- Suitable for municipal roads, industrial roads, and access roads
- Review road width, pole height, spacing, and mounting arm before quotation
- IES/LDT and DIALux / Relux support can be prepared after project inputs are confirmed
- Datasheet and BOQ matching notes are available where applicable
EPLUS DA — Double-Arm LED Street Light
EPLUS DA is used for projects where one pole supports lighting on two sides or where wider road layouts require coordinated optical distribution. Before selection, confirm pole arrangement, mounting height, arm direction, road width, target lighting class, voltage, SPD level, and simulation requirements.
- For double-arm road lighting and center-pole layouts
- Suitable for boulevards, dual carriageways, highways, and wide municipal roads
- Check two-side optical distribution and uniformity requirements
- Confirm mounting arm, pole height, road width, and spacing before selection
- IES/LDT and DIALux / Relux review can support consultant or tender-stage projects
EPLUS-JG — LED Street Light Head / Retrofit Lighting
EPLUS-JG is used when the project keeps the existing poles but replaces the luminaire head. Retrofit selection should review existing arm size, mounting interface, pole height, road width, voltage, old fixture type, lighting target, and required document support.
- For existing pole retrofit and luminaire replacement
- Suitable for municipal upgrade programs and road lighting renovation
- Check existing mounting arm, top diameter, voltage, and wiring condition
- Useful for BOQ model mapping and tender clarification
- Datasheet, IES/LDT, retrofit notes, and DIALux support can be prepared where required
Need help matching a series to your road lighting project?
What We Deliver for LED Street Light Projects
Project Support Deliverables
Model Recommendation
We review road width, pole height, spacing, mounting arm, voltage, optics, SPD level, and project requirements to recommend a suitable AC LED street light path.
Why it mattersAvoids wattage-only selection and wrong fixture matching.
Lighting Layout Support
IES/LDT files and DIALux / Relux support can be prepared after road layout, mounting height, spacing, target lux, and product configuration are confirmed.
Why it mattersSupports consultant review, EPC comparison, and tender-stage lighting checks.
Lead Time & Shipment Plan
We help review order quantity, packaging method, shipment schedule, and project delivery stage so procurement timing can match site or tender requirements.
Why it mattersReduces delivery uncertainty for EPC and municipal replacement programs.
Warranty, Spares & Installation Path
Warranty terms, spare parts, installation guidance, and handover documents can be reviewed according to confirmed project scope and product configuration.
Why it mattersHelps long-term maintenance planning and after-sales coordination.
Core Components for AC Road Lighting Reliability
Optical Distribution
Lens type and beam distribution should match road width, pole height, pole spacing, mounting angle, and target lighting level.
Key checkConfirm Type II / Type III or required optical distribution before IES / DIALux review.
LED Driver & SPD
Driver configuration and surge protection should match voltage, grid condition, cabinet status, lightning risk, and site environment.
Key checkConfirm AC input voltage, SPD level, and grid stability before quotation.
Housing & Heat Dissipation
Housing structure, thermal design, sealing, coating, and surface protection affect long-term performance in hot, humid, dusty, or coastal environments.
Key checkConfirm ambient temperature, humidity, coastal exposure, and IP / IK requirements.
Mounting & Pole Interface
Side-entry, post-top, arm length, arm angle, top diameter, and existing pole condition must be checked before retrofit or new installation.
Key checkConfirm pole height, arm size, mounting diameter, and installation method.
Need a model and document path for your LED street light project?
Manufacturing & Quality Evidence for LED Street Light Projects
Housing & Surface Review
Housing structure, heat dissipation, coating, sealing, and mechanical fit should be checked according to project environment and installation method.
Project relevanceImportant for hot, humid, dusty, coastal, or long-term municipal road lighting projects.
Optics & LED Module Check
Optical lens, LED module, beam distribution, CCT, and product configuration should match the selected road lighting application.
Project relevanceSupports IES / DIALux review, road lighting effect, and consultant approval.
Driver, SPD & Wiring Review
Driver, SPD, wiring, connector, input voltage, and electrical protection should be checked before bulk order and shipment.
Project relevanceReduces mismatch risk for AC grid, retrofit, and voltage-sensitive projects.
Aging Test, Label & Packing
Aging test reference, label information, packaging method, and shipment preparation help support project handover and site coordination.
Project relevanceUseful for EPC delivery, tender documents, batch inspection, and after-sales tracking.
Production & Inspection References
Before Shipment Review Items
01
Model & Quantity
Confirm selected model, quantity, mounting method, and project schedule.
02
Voltage & Driver
Check AC input voltage, driver configuration, and wiring requirement.
03
Optics / IES File
Confirm optical distribution and available IES/LDT file for lighting review.
04
SPD & Protection
Review surge protection, IP/IK requirement, and installation environment.
05
Label & Packing
Check model label, carton mark, packing method, and traceability information.
06
Shipment Documents
Review packing list, invoice, document pack, or tender files where applicable.
Review manufacturing and QC evidence for your LED street light order
Reference Projects for Road Lighting
Selected Public Road and Infrastructure Lighting References








Project Reference List
- Togo road lighting program, 2010-2024: 13,000 sets
- Ghana public road lighting program, 2015-2020: 12,000 sets
- Cote d'Ivoire road lighting project, 2012: 890 sets
- Nepal public lighting project, 2022: 200 sets
- 2025 high mast lighting project, Lusaka, Zambia
- Cambodia public lighting program, 2023: 12,000 sets
- Additional project references available on request
FAQ for AC LED Street Light Projects
Before You Ask for Price
- Road width / area size
- Pole height and spacing
- Mounting arm and installation method
- AC voltage and grid condition
- Target lux / lighting class
- Required IES, DIALux, datasheet, BOQ, or drawings
Request LED Street Light Project Configuration
What to Prepare Before Quotation
Useful inputs:
- Country / city and project type
- Road width or area size
- Pole height and spacing
- Mounting arm or installation method
- AC input voltage and grid condition
- Target lux / lighting class if available
- Required IES, DIALux, datasheet, BOQ, or drawings
- Retrofit or new-build project condition
LED Street Light RFQ Form
LED street light review paths
For AC LED road lighting projects, match model selection to road layout, lighting files, BOQ context, and document stage.
Submit LED Street Light Project Requirements | Request DIALux / Relux Support | Request IES / LDT File | Request Tender / BOQ Review | View Quotation Comparison Checklist
Available documents depend on confirmed project scope, product configuration, tender requirements, and document stage.