SL-SPL-HC SERIES

SL-SPL-HC Split Solar Street Light System

Choose the SL-SPL-HC when the lamp needs to light a specific stretch of road but the best spot for the solar panel is elsewhere. The separate, above-ground battery enclosure also lets you plan access for future inspection and replacement. Send us a site photo or road sketch. We’ll help you work out where the panel and battery can go and match the lamp and optics to your road layout, lighting hours and local sunlight. Separate solar panel · Accessible battery enclosure · Project-specific optics
SL-SPL-HC split solar street light with PV module underside, pole-mounted external enclosure and road luminaire.
Representative split-system arrangement

SL-SPL-HC Series at a Glance

The four SL-SPL-HC models use the same split-system concept, while PV and battery capacity are matched to your lighting schedule and local sunlight.

Lighting Design
Road Layout
We match the lamp and optics to your road width, pole height and spacing.
Battery Platform
12.8 / 25.6 V
We match battery voltage to the selected lamp and controller.
PV Module Range
100–250 W
Monocrystalline modules selected for worst-month solar resource and battery recovery.

Final module efficiency follows the approved PV datasheet.

Battery Chemistry
LiFePO₄
Long-cycle battery selection; cycle-life data follows the selected battery specification.
Charge & Lighting Control
MPPT
MPPT charging with programmed lighting schedules; smart-control options where specified.
Warranty
5 Years
For the supplied system under the agreed configuration and written warranty terms.

Choose Your SL-SPL-HC Model

Start with a site photo or rough road dimensions. If you have them, send the road width, pole height and spacing, the lighting level you need and how long the lights should run each night. We can help shortlist a lamp and optic, then match the solar panel and battery to the site and lighting schedule.

Model Battery Platform Reference PV Reference Battery Energy Luminaire Body Size L × W × H (mm) Reference Mounting Height**
SL-SPL-HC-60 12.8 V 120 W 80 Ah / 1,024 Wh 552 × 200 × 103 mm 6–8 m
SL-SPL-HC-80 25.6 V 150 W 55 Ah / 1,408 Wh 614 × 250 × 100 mm 8–10 m
SL-SPL-HC-100 25.6 V 200 W 65 Ah / 1,664 Wh 614 × 250 × 100 mm 9–12 m
SL-SPL-HC-120 25.6 V 250 W 80 Ah / 2,048 Wh 681 × 260 × 103 mm 10–14 m

SL-SPL-HC-60

Battery 12.8 V · reference PV 120 W Reference battery 80 Ah / 1,024 Wh Luminaire body 552 × 200 × 103 mm Reference mounting height 6–8 m

SL-SPL-HC-80

Battery 25.6 V · reference PV 150 W Reference battery 55 Ah / 1,408 Wh Luminaire body 614 × 250 × 100 mm Reference mounting height 8–10 m

SL-SPL-HC-100

Battery 25.6 V · reference PV 200 W Reference battery 65 Ah / 1,664 Wh Luminaire body 614 × 250 × 100 mm Reference mounting height 9–12 m

SL-SPL-HC-120

Battery 25.6 V · reference PV 250 W Reference battery 80 Ah / 2,048 Wh Luminaire body 681 × 260 × 103 mm Reference mounting height 10–14 m

** Reference mounting-height ranges are preliminary selection guides, not road-lighting design approvals. Final pole height, spacing and optic require project photometric calculation. PV and battery pairings are preliminary and must be recalculated for the site.

Common Lighting Specifications

Parameter Specification / Project Option
System efficacy ≥200 lm/W
CCT 6000 K standard; 3000 / 4000 / 5000 / 6500 K project options
Optical distribution Type II / Type III / Type IV options; select with matched photometry
Photometric files Model- and optic-matched IES / LDT, requested for engineering review
Dimming Time control, light control and programmable schedules
Ingress protection Battery enclosure IP65; luminaire IP/IK confirmed in selected submittal
Operating temperature Confirmed against the selected luminaire, battery and controller

Configure the Energy System for the Project

LED wattage alone cannot determine PV and battery size. Review the nightly operating profile, autonomy target, usable battery energy and worst-month solar conditions together.

SL-SPL-HC-60
Selected luminaire
Reference PV 120 W Battery Platform 12.8 V Reference Battery 80 Ah Nominal Energy 1,024 Wh

Preliminary energy configuration. Recalculate for the actual operating profile and solar resource.

SL-SPL-HC-80
Selected luminaire
Reference PV 150 W Battery Platform 25.6 V Reference Battery 55 Ah Nominal Energy 1,408 Wh

Preliminary energy configuration. Recalculate for the actual operating profile and solar resource.

SL-SPL-HC-100
Selected luminaire
Reference PV 200 W Battery Platform 25.6 V Reference Battery 65 Ah Nominal Energy 1,664 Wh

Preliminary energy configuration. Recalculate for the actual operating profile and solar resource.

SL-SPL-HC-120
Selected luminaire
Reference PV 250 W Battery Platform 25.6 V Reference Battery 80 Ah Nominal Energy 2,048 Wh

Preliminary energy configuration. Recalculate for the actual operating profile and solar resource.

Inputs Required for Energy Sizing

Nightly Operating Profile

Total operating hours and the power level needed in each time period.

Dimming Schedule

Confirm the output schedule rather than assuming full rated power all night.

Autonomy Target

Define reserve operation and minimum light output during low-solar periods.

Worst-Month Solar Resource

Use site irradiation and shading, not an annual-average assumption.

Temperature & System Losses

Allow for battery temperature, wiring, conversion, ageing and other losses.

Controller / Communication Demand

Include controls and communications loads where applicable.
Engineering Example

Why energy margin matters

In the illustrative 80 W dimming example, 150 W PV × 4.5 sun hours × 80% yield gives 540 Wh/day. LED-only demand is 80 W × 6.5 equivalent full-power hours, or 520 Wh/night. The 20 Wh/day margin disappears if auxiliary loads, losses or a poorer solar month increase demand or reduce generation.

This is an illustrative balance, not a site yield or autonomy guarantee. Extended 4–5-night reserve needs a new PV, battery and operating-profile calculation.

Think about the hours when the road is busiest, then the lighting still needed later at night. We use that schedule to compare energy demand with the proposed battery and solar panel. Two offers with the same amp-hour figure can store different amounts of energy when their voltages differ. Ask for watt-hours as well as voltage and capacity. A larger battery can provide more storage, but the panel also needs to replenish it under local seasonal sunlight. We can help compare those parts together, so a cheaper quotation does not hide a shorter lighting schedule or a different supply scope.

Independent PV & Battery Placement

A split architecture allows PV orientation, luminaire aiming and above-ground energy access to be planned separately within one coordinated pole and cable system.

Road Luminaire

Die-cast aluminium road luminaire with a replaceable internal light-source assembly. Optic and output are selected for the road layout and photometric requirement.

External PV Module

High-efficiency monocrystalline PV module with project-selected power and support arrangement. Orientation and tilt are reviewed for local solar access and shading.

Above-Ground Battery & Controller

LiFePO₄ battery and MPPT controller in an external above-ground enclosure for inspection and component access. The specified battery enclosure is IP65.

When a Split System Makes Sense

Independent solar orientation: PV tilt and direction can be set separately from light aiming. Accessible energy components: above-ground placement supports inspection planning. Flexible energy sizing: separate PV and battery components can be specified for the site’s operating profile.

SL-SPL-HC split solar street light with PV module underside, support bracket, under-panel enclosures and LED road luminaire on a pole.
Under-panel enclosure arrangement. Final components follow the approved project drawing.

Battery at the PV Support

Plan the module, bracket and enclosure together. Check support loads, access clearances, shading and cable protection against the project drawing.

Pole-Mounted Battery Enclosure

Set an accessible above-ground position and confirm clamp capacity, cable route and the maintenance approach. This series does not use an underground battery arrangement.

SL-SPL-HC split solar street light with PV module underside, pole-mounted external enclosure and LED road luminaire.
Pole-mounted enclosure arrangement. Final component specification follows the project design.
SL-SPL-HC PV support underside with bracket and under-panel enclosure mounting positions.
PV Support & Enclosure Mounting Detail — exterior view.

Detail view: the PV support and exterior enclosure positions. Internal assembly and final bracket geometry follow the approved component and project drawings.

Lighting & Optical Configuration

Road-lighting performance depends on more than LED wattage. Luminaire efficacy, optical distribution, mounting height, pole spacing and matched photometry must be reviewed together.

System efficacy≥200 lm/W; final performance follows matched photometric data
LED packages5050 / 5054 / 7070, selected for the order
CCT6000 K standard; 3000 / 4000 / 5000 / 6500 K options
Optical distributionType II / Type III / Type IV options; matched optic required
DimmingTime and light control with a programmable output schedule
Design fileIES / LDT matched to model, optic and output setting; requested for engineering review

Project Lighting Design Inputs

Road Geometry

Road width, carriageway, pedestrian areas and luminaire arrangement.

Mounting Height & Pole Spacing

Use project geometry rather than selecting the model from wattage alone.

Optic / Photometric File

Use the IES / LDT file matched to the selected luminaire and optic.

Target Lighting Criteria

Confirm required illuminance, uniformity or road class from the project specification.

Submit road width, pole height and spacing, outreach, aiming and target criteria for a model- and optic-matched IES / LDT and DIALux review. Check lighting at each reduced-output stage.

Start With The Darkest Part Of The Road

Tell us which parts of the road people use after dark: the carriageway, footpath, junction or entrance. A bright patch directly below a lamp can hide a darker stretch between poles. We use your road dimensions and the selected optic to review that distribution, including the lighting needed at the least-lit points. If the owner has a local lighting standard, send it with the layout. We can help organise the information for an IES-based calculation and discuss changes to spacing, aiming or the lamp selection with your team.

Mechanical & Mounting

Already have poles? Send a photo of the pole top or lamp arm and any mounting dimensions you have. We can check the lamp connection and where the panel and battery enclosure can fit, then identify any brackets or wiring you may need. The dimensions below are for the lamp head.

Luminaire Body Sizes

SMALL HOUSING
552 × 200 × 103 mm

Model: SL-SPL-HC-60

Reference mounting height: 6–8 m

MEDIUM HOUSING
614 × 250 × 100 mm

Model: SL-SPL-HC-80 / 100

Reference mounting height: HC-80: 8–10 m; HC-100: 9–12 m

LARGE HOUSING
681 × 260 × 103 mm

Model: SL-SPL-HC-120

Reference mounting height: 10–14 m

Mounting & Support Check

Luminaire: side-entry or post-top; Ø60 / Ø76 / Ø83 / Ø89 mm interfaces with a matched adaptor. Adjustment is 0–30°.

PV bracket: typically 0–45° mechanical adjustment; final tilt and support are site-specific.

Battery enclosure: above-ground aluminium-alloy box, IP65 at its specified closure and cable entries.

Confirm pole strength, PV projected area, enclosure loading, bracket, fixings, grounding, cable protection and foundation for the site. Share the site wind requirements and pole drawing so the support arrangement can be reviewed for your installation.

SL-SPL-HC luminaire side view showing the pole mounting interface and housing profile.
Luminaire side profile and pole interface; final adaptor follows the project drawing.

Keep The Useful Parts Of Your Existing Installation

Show Us The Connections

For a replacement project, send close-up photographs of the pole top, arm connection and any existing panel support. Include a ruler or the available drawing where possible. We help compare these connections with the proposed HC lamp and enclosure arrangement. This gives your installer a practical list of adaptors, clamps and cable connections to check before equipment is ordered, rather than discovering a mismatch when the shipment reaches the site.

Compare Equipment And Complete Packages

You may already have poles or a local contractor for foundations. Tell us what your team will provide, and we can organise the HC proposal around the remaining equipment. For a complete package, identify the lamp, panel, battery, controller, pole, arm and foundation hardware separately. This makes it easier to compare delivered cost and discuss local installation work without paying to import parts you already have.

Plan Access Before Installation

An above-ground enclosure is useful when its location works for the maintenance team. Consider how a technician will reach it, isolate the equipment and remove a replacement part. Panel position also affects shade and the cable route. We help coordinate the supplied components with the installation drawing, while your site team checks the existing pole, foundation and safe working arrangements for the extra equipment.

Serviceability & Maintenance

Split-system service points are separated across the luminaire, PV support and above-ground energy enclosure. These images identify exterior access locations.

SL-SPL-HC road luminaire underside showing the optic panel and exterior housing fasteners.

Replaceable Light-Source Assembly

Matched internal assembly can be replaced while retaining an undamaged luminaire housing. Individual LED packages are not field-replacement items.

SL-SPL-HC above-ground enclosure mounted to a pole with external clamps.

Above-Ground Battery Access

Position the external battery enclosure on the pole or near the PV support for above-ground inspection and replacement planning.

SL-SPL-HC enclosures positioned beneath the PV support on the pole.

Controller Access

The MPPT controller is housed with the battery in the external enclosure. Replacement settings must match battery, PV and LED output.

SL-SPL-HC PV support underside with bracket and under-panel enclosure mounting positions.

Independent PV Service

Inspect PV orientation, shading, module surface, support, cable route and connections separately from luminaire aiming.

Exterior views identify service locations. Internal access and replacement procedures follow the approved manual and project drawing.

Make Later Maintenance Easier For Your Team

Agree The Sample Before Production

We agree the sample and key components with you before production. For HC, that discussion includes the selected lamp, optics, external energy enclosure and their connections. Your team can use the same reference when reviewing the batch. If a component needs to change, we explain the effect and work through your approval, including the owner’s approval when required, before using the replacement.

Choose Useful Spare Parts

We discuss spare-part quantities before dispatch so they reflect the order and your maintenance arrangements. Keeping a record of the battery voltage, controller settings, lamp version and connectors helps identify the correct replacement later. When reporting a fault, photographs of the component label, installation and visible connections help us understand what your technician is seeing and advise the next check.

Keep A Clear Handover Record

Keep the agreed component list, drawings, sample reference and packing information together for receiving and installation. These records also help when the owner reviews the project several years later or a new maintenance team takes over. We help organise the supplied equipment information for that handover, reducing avoidable questions about which parts were approved and delivered. A clear record helps your team handle later maintenance questions, acceptance checks and audits.

TENDER & ENGINEERING FILES

Engineering Documents & Tender Support

Request files for the selected HC model, optic, PV, battery, controller and procurement stage. The submission should describe the equipment proposed for supply.

Model-Matched Datasheet

Electrical, optical and mechanical data for the selected luminaire and energy configuration.

Download SL-SPL-HC-60 / 80 / 100 / 120 Technical Datasheet (PDF) — Issue 2026.10

IES / LDT & DIALux

Photometry matched to the luminaire and optic, with lighting calculations based on agreed road geometry.

Energy / Battery / PV Review

Nightly demand, worst-month solar resource, storage, reserve output and recovery reviewed together.

Drawings / BOQ / Tender Support

Mounting drawings, enclosure coordination, BOQ mapping and technical deviations for the defined supply scope.

Send your owner’s document checklist and deadline. We help put together the datasheet, matching photometric file, mounting information and component list for your selected HC system, so your team can present a consistent proposal and answer the reviewer’s questions.

See photometric file support and tender and BOQ review.

Preparing a bid before every site detail is available? Send the specification pages you have and tell us the submission date. We help separate the information needed for the initial proposal from the measurements your installer will need next. A road photograph, rough layout and the owner’s lighting requirements can start that discussion. As the proposal develops, the HC component list and requested files give your buyer, consultant and installer a common reference for the equipment being considered.

SL-SPL-HC FAQ

Answers for project selection, energy sizing, installation and the files your project team needs.

What is the main difference between a Split and All-in-One solar street light?

A Split system places the road luminaire, PV module and LiFePO₄ battery enclosure separately, so solar direction, light aiming and service access can be planned independently. An All-in-One product integrates these elements more closely. Choose the architecture from pole layout, solar exposure, maintenance access and installation scope.

Start with the nightly operating profile, dimming stages, minimum reserve output and target autonomy. Add controller and communications demand, conversion losses, usable battery capacity, temperature and ageing assumptions. Select PV from worst-month irradiation, shading, electrical compatibility and recovery after low-sun periods. The published PV and battery examples are engineering starting points only.

No. The current SL-SPL-HC series uses above-ground battery enclosures, either pole-mounted or positioned at or beneath the PV support. Confirm access, support and cable routing for the selected arrangement.

Yes. The PV bracket is typically adjustable over 0–45° for site-specific solar orientation, while the luminaire can be aimed over 0–30° for the road-lighting layout. Final settings and structural support follow the project drawing.

Yes. Send the road layout, lighting requirements and HC model you are considering. We help match the IES / LDT file to the lamp, optic and output setting, then use your road geometry for the DIALux or Relux review. Your team can use the resulting proposal to discuss coverage, spacing and the lighting target with the owner.

Begin with road width, pole height and spacing, required illuminance and uniformity, operating hours, dimming, autonomy, solar conditions and the BOQ. The mounting heights listed by model are starting points. Confirm the final model with matched photometry and an energy calculation; wattage alone is insufficient.

Request SL-SPL-HC Project Configuration

Tell us where the lights will go and what you need help with. A short description is enough to start. If you already have poles, we can list the equipment and mounting parts you need. If you need a complete package, we can list the lamp, panel, battery, controller, pole and foundation hardware separately so you can compare the scope. The button opens the Split project form. Mention SL-SPL-HC in your message.

PLANNING A SOLAR STREET LIGHTING PROJECT?

Share your project location, estimated quantity and requirements.
We’ll review the suitable configuration and supply scope for your project.