Togo Road & Highway Solar Street Lighting Project
Reference deployment delivered for EPC and tender workflows.
Includes typical configuration range and deliverables (IES / BOQ) with acceptance notes.
| Country / Region | 🇻🇳 Vietnam |
| Road Type | Main road sections |
| Client Type | EPC / contractor (tender workflow reference) |
| System Type | AC LED street lighting (section-based configuration) |
| Quantity | 500 sets |
| Pole Height | 6 m (project reference) |
| Power Range | 50–80 W (60 W reference) |
| Optics | IES Type II / Type III (selected by road width) |
| Input Power | 220–240VAC, 50Hz (wide voltage on request) |
| Key Deliverables | IES/LDT + layout outputs + BOQ mapping notes |
Note: Values shown are a project reference range; final configuration is verified per section using IES/LDT and layout outputs.
Project Background
This Vietnam main road reference (6m poles, 500 sets) was prepared to support EPC tender workflows and reviewer checks.
Key layout assumptions (pole height, spacing per section, optics by road width) are documented and tied to auditable deliverables, including IES/LDT photometry, layout verification outputs, and BOQ matching notes.
Practical installation and acceptance notes are included to reduce site risk and rework during commissioning.
Technical Configuration (Project Reference)
- ✓ Roadway optics: IES Type II / Type III options with IES/LDT files for layout verification
- ✓ Pole reference: 6m poles; spacing documented per section and verified by outputs
- ✓ Luminaire range: 50–80W (60W reference) with tender-friendly spec range and wiring notes
- ✓ Input power: 220–240VAC, 50Hz (wide voltage on request)
- ✓ Protection: IP66 / IK08 with surge protection 10kV standard (20kV optional)
- ✓ Deliverables mapping: IES/LDT + layout outputs + BOQ mapping notes for EPC review
Scope & Assumptions
A concise summary of what this reference covers and the verification inputs behind it.
Scope (Vietnam Main Road)
- Coverage: main road sections (tender-style reference)
- Use case: EPC / tender workflows requiring verifiable assumptions
- Deliverables referenced: IES/LDT + layout outputs + BOQ mapping notes
- Configuration approach: 6m pole package with section-based spacing and optics selection
Verification Inputs (Assumptions Documented)
- Pole height: 6m (fixed for this reference)
- Spacing: documented per section and verified by IES + layout outputs
- Optics: IES Type II / Type III selected by road width
- Targets: maintained lux & uniformity per project brief (simulation supported)
- Controls: dusk-to-dawn operation (no dimming / no smart CMS)
Detailed verification inputs can be shared in a redacted pack or under NDA for tender review.
Photos & Acceptance Notes
Field photos confirm the deployment is real. The notes below summarize typical site acceptance checks used by EPC teams to reduce rework and sign-off risk.
Acceptance Notes (Typical)
✓ Bracket / Arm Interface
Verified against drawings (spigot size, orientation).
✓ Wiring & Polarity
Checked before commissioning; glands sealed.
✓ Controller Label / ID
Recorded for traceability (batch/serial).
✓ Pole Verticality & Base
Checked after installation (base fastening).
✓ Dimming Profile
Applied and verified with timestamps (log/screenshot).
✓ Lux Spot-Check (Optional)
Performed on a representative section.
Tip: Full checklist and traceability tables can be shared in a redacted pack or under NDA.
Deliverables Provided
Reference deliverables available for tender review and verification. Browse samples in the resource pages or request a project-ready pack.

IES / LDT Photometric Files
Browse IES files used for roadway optics verification and layout checks. Suitable for EPC submissions and audit trails.

BOQ (Bill of Quantities)
Review BOQ examples aligned to scope, accessories, and configuration ranges for procurement and budgeting.

Drawings & Acceptance Checklist
Download or request CAD drawings, installation details, and datasheets for approvals.

DIALux / Relux Outputs
See report samples and typical verification items (maintained lux, uniformity, assumptions, and result tables).
FAQ (Tender & Verification)
Quick answers to common EPC / tender questions for this reference.
Is this project AC (grid-powered) street lighting or solar?
This reference is for AC LED street lighting (grid-powered). It is prepared for EPC tender workflows and reviewer checks.
What documents can you provide for tender submission?
A tender-style redacted pack can include IES/LDT photometry, layout verification outputs, and BOQ mapping notes.
Full deliverables and supporting notes can be shared under NDA if required.
Do you provide IES/LDT files and layout outputs for verification?
Yes. This reference documents key assumptions (6m poles, spacing per section, optics by road width) and provides verification-ready outputs for consultant review.
How do you handle different road widths and spacing across sections?
We document section-based assumptions and select roadway optics (Type II / Type III) by road width and layout.
Spacing and targets are recorded per section and supported by IES + layout outputs.
Does this reference include smart control or dimming profiles?
No. This reference is configured for dusk-to-dawn operation without scheduled dimming or smart CMS.
If your tender requires dimming or monitoring, we can provide an optional configuration range and documentation.
What inputs do you need to propose a similar package in 24 hours?
Share road type, targets (maintained lux / uniformity), pole height, layout constraints (spacing/arrangement), and your submission checklist.
If available, attach a site sketch or CAD for faster alignment.
Get in Touch with Sunlurio Manufacturer
Feel free to ask any question to us
Sunlurio street light manufacturer replies within 24 hours with factory-direct support, technical suggestions and quotations for solar or LED street lighting projects.
- Linrui Business Plaza, Huangdao District, Qingdao,China
- 0532-83978013
- 0532-83978023
- 0086-18653218098
- info@sunlurio.com
- Mon - Fri: 9:00am - 6:00pm